Not long ago someone even told me that in florida roofing companies won t let their workers go up on roofs with open cell spray foam because the roofs are so spongy the guys fall right through.
Hot roof closed cell spray foam.
It doesn t fill the cavity though so spot checks may be required to check you don t get shorted.
And again to reiterate hot roof or hot attic assemblies where the foam is beneath the roof deck are okay.
Closed cell spray foam.
Todd miller isaiah industries inc.
The main drawback is high cost.
Murmurs and hearsay about open cell spray foam insulation have been gaining traction for a while.
Closed cell spray foam uses blowing agents with a high global warming potential and open cell spray foam needs a.
Unless you live in climate zones 2b or 3b desert area s in texas new mexico arizona california the codes and common sense will point you to closed cell foam.
This roof assembly is often referred to as a cold roof and is the antithesis of a hot roof.
Instead i like to build a fully vented roof assembly that is insulated with closed cell spray foam.
Closed cell foam has a higher r value per inch and installers generally spray 2 in walls and 3 in roof lines to meet the energy code requirements of r 13 and r 19 respectively.
The foam must be thick enough to meet minimum code requirements.
Closed cell or open cell foam.
Will i be looking at any problem with going to a metal roof.
If you want to use spray foam here s my advice.
With two strategies employed the airtight vapor impermeable foam plus the ventilation as a safety valve you might call this a belt and suspenders approach to building.
I plan to use the closed cell spray foam insulation on 3 4 inch sheathing.
Since it s air impermeable spray polyurethane foam can be installed alone on the underside of roof sheathing.
More common of the two types of spray foam closed cell is mostly used for commercial roofing.
The amount of closed cell spray foam or rigid insulation is somewhere between 20 to 50 of the r value of the overall cavity insulation depending on your climate zone.
With enough closed cell spray foam under the deck or enough rigid above the deck interior moist air can t condense if the there is no condensation you don t need drying thus no need to vent.
Both low density open cell and medium density closed cell spray foam can be used in an unvented attic to provide the needed thermal resistance and airtightness.
Since you have already arranged to have 2 inches of closed cell spray foam installed in your floor assembly it seems clear that there is at least one insulation contractor in your area who is willing to install closed cell spray foam.
There are fewer reports of problems with closed cell spray foam than with open cell spray foam.
Closed cell spray foam is made of cells that are encapsulated and pressed tightly together to prevent air and moisture penetration inside the foam.